Remove the gas component assembly, see above.

Mark all wires to be removed for proper reassembly. CAUTION: Wiring errors cause
improper and dangerous operation.

The convection blower is located at the bottom of the appliance at the back. Remove the
three screws holding the blower.

Lift the blower out and disconnect the wires from the blower.

REPLACING CONVECTION BLOWER

IF YOUR GLASS BREAKS

In the event your glass cracks or breaks, it must be replaced by the exact same size and
material. It is made from high temperature ceramic material. See replacement parts list and
contact your nearest Archgard dealer.

Remove door and carefully remove all traces of glass and gasket material.

Replacement requires Ceramic glass part #307-0042, gasket part #314-0007 and sealer
part #319-0005.

Install new glass with new gasketing in place. The “thicker” side of the gasket fits against
the fireplace opening.

Hold glass in place by using the sealer between gasket and door. Use sparingly so that no
excess will be visible. DO NOT PUT ANY SEALER BETWEEN GLASS AND UNIT
OPENING.

Replace the door carefully making sure all three clamps are closed.

SERVICING

Cont...

CONVERTIBLE PILOT ORIFICE

The pilot assembly is convertible to the type of
gas being used. Simply unscrew the body by
using a 7/16” (11 mm) wrench and turn ¼
open - then push the small metal tab across to
the other side of the body and retighten. Call
your local Authorized Archgard Dealer to
purchase the correct fuel conversion kit
for your gas appliance.

7/16”

(11 mm)

WRENCH

(HERE)

Advertising