Dvie33 – Archgard 31-DVIE33N User Manual

Page 11

Advertising
background image

31-DVIE33

11

8”

(204 mm)

CLEARANCES TO COMBUSTIBLES

TOP VIEW

SIDE VIEW

Clearances to Door Frame

Sidewalls or Mantle Supports

CAUTION: This appliance is designed for use in any masonry or factory-built, wood-burning
fireplace. It cannot be enclosed by combustible material and used as a built-in gas fireplace.

WARNING: Failure to position the parts in accordance with these diagrams or failure to use
only parts specifically approved with this appliance may result in property damage or personal
injury or loss of life.

Combustible mantle allowed in
shaded area. Mantle extension
maybe increased 1” (25.4 mm) for
each additional 1” (25.4 mm)
increase in clearance height.
Example: If using a 5” (127 mm)
reduce minimum height to
31” (788 mm).
If using a 4” (102 mm) reduce
minimum height to 30” (762 mm)

12” (305mm)

Minimum Height

From Bottom of

Appliance: 38”

(966 mm) with a

12”(305 mm) mantel.

Note:
If existing wood fire-
place hearth protection
is removed it must be
replaced by a non-
combustible hearth
protection 7” thick,
extending a minimum
of 16” (406 mm) from
the front of the fire-
place insert or have a
minimum 7” (178 mm)
clearance below the
level of the bottom of
the insert.

Minimum 8” (204 mm)
clearance is required from the
glass door frame to a sidewall
or mantle support.

7”(178mm)

Minimum clearance

to combustibles

framing

Non– Combustible Zone

16”(406mm)

8”

(204 mm)

Advertising