Dvie33 – Archgard 31-DVIE33N User Manual

Page 6

Advertising
background image

31-DVIE33

6

This appliance was listed by LABTEST Certification Inc to the following USA and Canadian gas
appliance standards.

- ANSI Z21.88-2009/CSA 2.33-2009 Vented Gas Fireplace Heaters

- CAN/CGA-2.17-M91, Gas-Fired Appliances for Use at High Altitudes

-CSA P.4.1-09 testing method for measuring annual fireplace efficiency.

The listing label is attached to the appliance on the bottom right side of the appliance.

A copy is shown on page

Please contact Archgard Industries Ltd., if you have any questions regarding the certification of
this appliance.

APPLIANCE CERTIFICATION

INSTALLATION CODES

This appliance must be installed by a qualified gas appliance installer. The installation must
conform with the local codes or, in the absence of local codes, with the current National Fuel
Gas Code ANSI Z223.1/ NFPA 54 in the US, or Installation Code CAN/CGA-B149.1 in
Canada. Electrical connections and grounding must conform with local code, or current
National Electrical code ANSI/NFPA No. 70-1987 in the US, and in Canada the current
Canadian Electrical Code CSA C22.1.

We recommend that our gas hearth products be installed and serviced by professionals
who are certified in the U.S. by the National Fireplace Institute® (NFI) as NFI Gas
Specialists.

Natural Gas (NG)

Propane (LP)

Manifold Pressure

3.5 in. W.C. (0.9 kPa)

10.0 in. W.C. (2.5 kPa)

Min. Supply Pressure
Max Supply Pressure

5 in. W.C. (1.2 kPa)

14.0 in. W.C. (3.5 kPa)

11.0 in. W.C. (2.8 kPa)
14.0 in. W.C. (3.5 kPa)

Orifice Size

#33 DMS (2.87 mm dia)

#51 DMS (1.73 mm dia)

Nominal Input Rating

22,000 - 33,000 BTU/hr (6.1- 9.6kW) 24,000 - 31,000 BTU/hr (6.9 -9.0kW)

Electrical Rating

120 VAC, 60Hz less than 2 A. /

120 VAC, 60Hz less than 2 A. /

Gas Control

SIT 885 Proflame

SIT 885 Proflame

Altitude

0 - 4,500 ft. (0 - 1372 M)

0 - 4,500 ft. (0 - 1372 M)

Primary Air Opening

1/4” (6 mm) OPEN

FULLY OPEN

HIGH ALTITUDE INSTALLATION

When installing this appliance beyond 4500 ft. (1372 M) above sea level, the appliance must be
properly de-rated and installed according to local codes, in the absence of local codes, with the
current National Fuel Gas Code, ANSI Z223.1/ NFPA 54, in the US or Installation Code, CAN/CGA-
B149, in Canada.

SPECIFICATIONS

Advertising
This manual is related to the following products: