Dvie33 – Archgard 31-DVIE33N User Manual

Page 15

Advertising
background image

31-DVIE33

15

Before placing the appliance into the fireplace, check the hearth of the fireplace to see if it is level
with the front of the fireplace. If it is not, measure the depth of the hearth. Loosen the three screws of
the leveling “L” bracket at the back of the appliance. Lower it to the measurement obtained and
tighten the screws.

APPLIANCE DESCRIPTION

ELECTRICAL CONNECTIONS

The 31-DVIE33 comes complete with an adjustable 6 speed fan wired directly to the main control
module for your protection against shock hazard.

Do not cut or remove the grounding prong from this plug.

NOTE: This appliance, when installed, must be electrically grounded in accordance with local codes
or, in the absence of local codes, with the National Electrical Code, ANSI / NFPA 70, or the
Canadian Electrical code, CSA C22.1.

TOP VIEW

Intake

Exhaust

FRONT VIEW

Ceramic

Glass w/
standard

black

door

Surround

Faceplate

On/Off

Rocker

Rear Level

LEVELING THE 31-DVIE33

Front Level

Located slightly in from the front edge of the fireplace is the new level-
ing feature. Leveling bolts can be installed to enable you to raise the
front of the firebox if necessary. If you need higher adjustment you only
need to change to a longer bolt. If no rise is required simply leave
empty.

Advertising