GUIDE TO INSTALLATION AND OPERATION

28 | LGK-3901/DSK-3901

4.8.4 Temperature

Probe


The Temperature Probe feature requires the LGK-3901-OPT-TEMP option.

This option provides a low cost temperature sensor (Sensorsoft ST6154J) for measuring the local temperature,
typically from the roof of the building. The temperature is recorded in Celsius or Fahrenheit, and can be displayed
(and continually updated) on a keying layer of the LGK-3901 via an Easytext template.

The thermometer connects via cable to an RS232 serial port on the LGK-3901 and can be located up to a thousand
feet away without the need for a battery or external power adapter. It has an external stainless steel probe for outdoor
applications or where liquids are present.

4.8.4.1 Temperature Probe Parts

Miranda Part Number

Description

4100-0041-0

Sensorsoft ST6154J RS232 Temperature Sensor with External Probe

3503-0024-0 Sensorsoft

C2000

Cable, DB9-to-RJ45, 20 feet

1897-1700-100

Miranda Adapter, RJ45-to-DE-9 for RS232 DTE

0702-1400-100

Ethernet Cable, RJ45-to-RJ45 CAT5 UTP, Flex 10 feet


Note: For pin-outs to be correct at the LGK-3901, parts must be connected in the order listed in the table above.

4.8.4.2 Temperature Probe Serial Port Settings


The serial port protocol and baud rate must be set to the following values via the front panel or Configurator Tool:

• Protocol

ST61XX Temp Sens

• Baud

Rate

1200

4.8.4.3 Temperature Probe Easytext Templates


When the Easytext option (LGK-3901-OPT-TXT) is also enabled, the special Temperature Probe datasource names
(show in the table below) may be used for text boxes within any Easytext template used on the system. When the
Easytext option is not enabled, a special template name “temperature.oxa” is reserved for displaying the special
Temperature Probe datasources. This is the only Easytext file that can be displayed on such a system.

Temperature Probe Datasource Name

Displays

Accuracy

TEMPERATURE_CELSIUS Celsius

Rounds to nearest integer

TEMPERATURE_CELSIUS_TENTHS Celsius One

decimal

place

TEMPERATURE_FAHRENHEIT

Fahrenheit

Rounds to nearest integer

TEMPERATURE_FAHRENHEIT_TENTHS

Fahrenheit

One decimal place


Once an Easytext template has been generated containing one or more of the Temperature Probe datasource names,
then this can be loaded into a keying layer and cut up to display the temperature on-air.

Advertising