18

Installing the SSP-3801 card

Cabling the SSP-3801 card

Cabling the SSP-3801 card

Cabling the SSP-3801 depends upon your intended use. Note that the scope of this
document is limited to setting up the SSP-3801 card for basic start-up functionality. As
such, you should ensure that the following connections are made to the rear connector
panel of the SSP-3801 card.

• Connect a network Ethernet cable to the ETH1 Ethernet port. Note that the card is

setup to expect two network Ethernet cables, ETH1 as primary and ETH2 for
redundancy, which are set to be bonded by default.

• Connect the

PGM

(SDI Output) to downstream equipment such as a broadcast monitor

or a router input, for example.

• Optional - Connect an external reference source to

REF IN

• Optional - Connect HD/SD SDI source input to

A (SDI IN A)

Information about the remaining input-output connections are provided on

page 11

.

Figure 3-3. Basic SSP-3801cabling connections

Starting the SSP-3801 card

Once the SSP-3801 rear connector panel and card have been installed, power up the
Densité 3 frame and ensure that the card is running properly.

PGM SDI
Output

A SDI Input
(optional)

Ethernet
Port ETH1

REF IN
(optional)

Advertising