Installing the SSP-3801 card

Installing a second on-board solid state storage drive

Figure 3-4. positions of the SSDs

To install the second SSD:

1 Log into the card’s web interface. For more information see

Logging into the SSP-3801

card’s web interface

on page 24.

2 Obtain and enable the OPT 2SSD license. For information about how to enable a

license, see “Enabling or disabling a license option” in the User Guide.

3 From the menu, select Restart and click Safe Shutdown.

4 Once shutdown is complete, remove the SSP-3801 card from the Densité 3 frame.

5 Install the second SSD:

• Locate the first SSD in between the front and rear of the card. The second SSD is

installed next to the first SSD.

• Hold the SSD so that the SATA connectors are in the correct position to align with

the connectors on the rear of the card.

• Carefully insert the second SSD into position beside the first SSD and slide it into

the connectors ensuring that the connection is well made.

• Screw the SSD into place with the screws provided.

6 Replace the SSP-3801 card into the Densité 3 frame.

7 When the card has rebooted, verify that the SSD was installed correctly. To verify:

• Open and log into the SSP-3801 card’s web interface (see

page 24

).

• From the menu, select Status Information > System and click Partitions. In the

Media Cache Partition

section, the size should include the combined amounts of

First SSD

Location to install
the second SSD