TNC 406/TNC 306

3 Standard data transmission protocol

3/97

3.1.5 Reading in all programs

If both the peripheral unit and the TNC have been started, the following protocol is followed:

Peripheral unit

<NUL> <NUL>

1st line of file 1 <CR> <LF>

Last line of file 1 <CR> <LF>

<NUL> <NUL>

1st line of file 2 <CR> <LF>

Last line of file 2 <CR> <LF>

1st line of last file <CR> <LF>

<NUL> <NUL>

Last line of last file <CR> <LF> <ETX>

Transmission path

<DC1>

TNC

<EOT>

<DC1>

<DC1>

<DC1>

.

.

.

.

.

.

.

.

.

<ETX>

...

...

...

If several programs are gathered together in a file which ends with <ETX> then these programs are
read in without being requested by <DC1>.

Data read-in does not stop until a program has ended with <ETX>.