Probe configuration, Radial screen, 3 sof tw a re set u p – HEIDENHAIN ND 1200R User Manual
Page 69

ND 1200R Radial
69
2.3 Sof
tw
a
re
set
u
p
Probe configuration
The Radial screen contains data and choice fields for configuring a
probe.
Radial screen
The Radial screen configuration fields include:
Touch probe type
Probe size
Prompts for drilling
Side operation
Probe level
Probe debounce
To configure probe settings in the Radial screen:
Press MENU>SETUP to display the setup menu and then highlight
the Radial menu item.
Highlight the Touch Probe choice field and then press a soft key to
select the probe type.
Highlight the Probe Size data field and then enter the diameter of the
probe.
Highlight the Drill Prompts choice field and then press a soft key to
select prompting for drill changes.
Select a touch probe type
Enter a probe size
Select display of drill prompts