2 standard telegram 82, Standard telegram 82 – HEIDENHAIN PROFIBUS-DP (DPV2) User Manual
Page 40
Advertising

PROFIBUS IO data description
40
5.4.2 Standard telegram 82
Standard telegram 82 uses 4 bytes for output data from the
master to the encoder gateway and 14 bytes of input data from
the encoder gateway to the master.
Output data from the master:
2 bytes Control word 2 (STW2_ENC)
2 bytes Control word (G1_STW)
IO Data (word)
1
2
Set point
STW2_ENC
G1_STW
Input data to the master:
2 bytes Status word 2 (ZSW2_ENC)
2 bytes Status word (G1_ZSW)
4 bytes Position value 1 (G1_XIST1)
4 bytes Position value 2 (G1_XIST2)
2 bytes Velocity value A (NIST_A)
IO Data (word)
1
2
3
4
5
6
7
Actual value
ZSW2_ENC G1_ZSW G1_XIST1
G1_XIST2
NIST_A
Note: Telegram 82 is only supported by the encoder gateway.
It is not supported by the absolute encoder.