5.4.3 Standard telegram 83
Standard telegram 83 uses 4 bytes for output data from the
master to the encoder gateway and 16 bytes of input data from
the encoder gateway to the master.
Output data from the master:
2 bytes Control word 2 (STW2_ENC)
2 bytes Control word (G1_STW)
IO Data (word)
1
2
Set point
STW2_ENC
G1_STW
Input data to the master:
2 bytes Status word 2 (ZSW2_ENC)
2 bytes Status word (G1_ZSW)
4 bytes Position value 1 (G1_XIST1)
4 bytes Position value 2 (G1_XIST2)
4 bytes Velocity value B (NIST_B)
IO Data (word) 1
2
3
4
5
6
7
8
Actual value
ZSW2_ENC G1_ZSW
G1_XIST1
G1_XIST2
NIST_B
Note: Telegram 83 is only supported by the encoder gateway.