4 reading the preset value, Reading the preset value, Table 24 – HEIDENHAIN PROFIBUS-DP (DPV2) User Manual
Page 56: Read of preset value, parameter request, Table 25, Read of preset value, parameter response

Acyclic parameter data
56
7.3.4 Reading the preset value
The tables below show the structure of a read value request.
Read of preset value, parameter 65000, parameter request
Request reference
0x00
Request ID
0x01
0x01->read value
DO-ID (axis)
0x01
Drive object ID
No of parameters
0x01
0x01 Read one parameter
Attribute
0x10
0x10->value
No of elements
0x00
Parameter number
0xFDE8
Parameter 65000
Sub index
0x0000
Table 24
Read of preset value, parameter request
Read of preset value, parameter 65000, parameter response
Request reference
0x00
mirrored
Response ID
0x01
0x01->read value
DO-ID (axis)
0x01
mirrored
No of parameters
0x01
Format
0x04
0x04=data type unsigned 32
No of values
0x01
Values or errors
0x00,0x00x,
0x00,0x64
Preset value 100
Table 25
Read of preset value, parameter response