10 status word (g1_zsw), Status word (g1_zsw), Table 19 – HEIDENHAIN PROFIBUS-DP (DPV2) User Manual
Page 48: G1_zsw implementation requirements

PROFIBUS IO data description
48
5.10 Status word (G1_ZSW)
The status word defines encoder states, acknowledgements,
error messages of major encoder functions.
Bit
Function
0...7
Function status: Reference mark search,
measurement on the fly
8
Probe 1 deflected
9
Probe 2 deflected
10
Reserved, set to zero
11
Requirement of error acknowledgement detected.
12
Set/shift of home position executed
13
Transmit absolute value cyclically
14
Parking sensor active
15
Sensor error
Table 19
G1_ZSW implementation requirements
Note: If bit 13 Transmit absolute value cyclically or bit 15
Sensor error is not set there is no valid value or error
code transferred in G1_XIST2.
Note: Bit 13 Transmit absolute value cyclically cannot be set
at the same time as bit 15 Sensor error as these bits
are used to indicate either a valid position value
transmission (bit 13) or the error code transmission
(bit 15) in G1_XIST2.