Functionality in the PROFIBUS DPV2 device
87
8.14.5 Encoder specific parameter 65003- Operating status 64 bit structure
The parameter structure 65003 is only supported by the encoder
gateway and is a read only structure where information on the 64
bit parameter values can be found.
PNU
65003
Significance
Encoder operating status 64 bit
Data type
Array[n] Integer64
Access
Read
Validity range
Profile specific
Explanation
The operating status displays the status of the encoders
Table 54
Structure of 65003 Operating status 64 bit
Sub index
Meaning
0
Header
1
Offset value 64 bit
2
Measuring units per revolution 64 bit
3
Total measuring range in measuring units 64 bit
Table 55
Structure of 65003 Operating status 64 bit
Note: The parameter 65003 is only supported by the encoder
gateway.