4 error message, Error message, Table 22 – HEIDENHAIN PROFIBUS-DP (DPV2) User Manual
Page 53: Sensor status word
Advertising

Alarms and warnings
53
6.4 Error message
Diagnosis information can be obtained by monitoring of the Error
bit in the Status word G1_ZSW (bit 15) and evaluation of the error
code transmitted in G1_XIST2.
Supported diagnosis
Error code in
G1_XIST2
Description
Sensor group error
0x0001
The encoder fails to read the correct
position value
Memory error
0x1001
The encoder fails to read the stored
offset or preset values from the non
volatile memory.
Command not supported 0x0F01
User parameter data assignment error
or command error in commands word
G1_STW and STW2_ENC.
Masters sign-of-life fault
0x0F02
The number of permissible failures the
controllers life sign was exceeded.
Table 22