PROFINET IO data description
47
4.11
Status word (G1_ZSW)
The status word defines encoder states, acknowledgements, er-
ror messages of major encoder functions.
Bit
0..7
Function status: Reference mark search, measure-
8
9
Probe 2 deflected position mode (Preset)
11
Requirements of error acknowledgment detected
Set/shift of home position (Preset) executed
Transmit absolute value cyclically
Note: If bit 13 Transmit absolute value cyclically or bit 15 Sen-
sor error is not set there is no valid value or error code
transferred in G1_XIST2.
Note: Bit 13 Transmit absolute value cyclically cannot be set
Advertising