Terminal functions, Refer to, Table 6 – Yaskawa 1000 Series Drive Option - Open Collector Type PG User Manual

Page 25: For details on, For a de, 5 installation procedure

Advertising
background image

5 Installation Procedure

YASKAWA ELECTRIC TOBP C730600 36C 1000-Series Option PG-B3 Installation Manual

25

Terminal Functions

Table 6

Option Terminal Functions

Terminal

Block

Terminal

Function

Description

TB1

<1> A separate UL-listed class 2 power supply is necessary when the PG requires more than 200 mA to operate.

A+

A+ pulse signal input

• Pulse signal inputs from the PG.
• Signal inputs from complementary and open-

collector outputs

• Signal level

H level: 8 to 12 V
L level: 2.0 V or less

A–

A– inverse pulse input

B+

B+ pulse signal input

B–

B– inverse pulse input

Z+

Z+ pulse signal input

Z–

Z– inverse pulse input

SD

NC pin (open)

For use when cables shields should not be grounded

FE

Ground

Used for grounding shielded lines

TB2

IP

PG power supply

• Output voltage: 12.0 V

± 5%

• Max output current: 200 mA

<1>

IG

PG power supply common

AO

A pulse monitor signal

• Outputs the monitor signal for the A, B, and Z pulses

from the PG speed control card

• For open collector outputs from the option
• Max voltage: 24 V
• Max current: 30 mA

BO

B pulse monitor signal

ZO

Z pulse monitor signal

IG

Monitor signal common

Advertising