7 Troubleshooting

30

YASKAWA ELECTRIC TOBP C730600 36C 1000-Series Option PG-B3 Installation Manual

The PG encoder is disconnected
or is not wired properly, or the
PG option or PG encoder are
damaged.

• Rewire the PG encoder and make sure all wiring including shielded wiring is

properly connected.

• If the problem continues after cycling power, replace the PG option or the PG

encoder.

Digital Operator Display

Fault Name

dv3

Inversion Detection

• Torque reference and acceleration are in opposite directions.
• The speed reference and actual motor speed differ by over 30% for the number

of pulses set to parameter F1-18.

Cause

Possible Solution

The Z channel pulse offset is not
set properly to E5-11.

Set the value for

Δθ to E5-11 as specified on the motor nameplate. Replacing the

PG encoder or changing the application so the motor rotates in reverse requires
readjustment of the Z channel pulse offset.

An external force on the load
side caused the motor to move.

• Make sure the motor is rotating in the proper direction.
• Investigate problems on the load side causing motor rotation in the opposite

direction.

Noise interference along the PG
encoder cable is affecting the A
channel or B channel.

• Rewire the PG encoder and make sure all wiring including shielded wiring is

properly connected.

• If the problem continues after cycling power, replace the PG option or the PG

encoder.

The PG encoder is disconnected
or is not wired properly, or the
PG option or PG encoder are
damaged.
The PG encoder rotational
direction set to F1-05 is in the
opposite direction of the motor
wiring.

Make sure motor wiring for each phase (U, V, W) is connected properly.

Digital Operator Display

Fault Name

dv4

Inversion Prevention Detection
Pulses indicate that the motor is rotating in the opposite direction of the speed
reference. Set the number of pulses to trigger inverse detection to F1-19.
Note: To avoid nuisance faults, be sure to disable inverse detection in applications
where the motor may rotate in the opposite direction of the speed reference. Set
F1-19 to 0 to disable this feature.

Cause

Possible Solution

The Z channel pulse offset is not
set properly to E5-11.

• Set the value for

Δθ to E5-11 as specified on the motor nameplate.

• If the problem continues after cycling power, replace the PG option or the PG

encoder.
Replacing the PG encoder or changing the application so the motor rotates in
reverse requires readjustment of the Z channel pulse offset.

Noise interference along the PG
encoder cable is affecting the A
or B pulse.

• Make sure the motor is rotating in the proper direction.
• Investigate problems on the load-side that may be causing the motor to rotate in

the opposite direction.