8 specifications, 8specifications – Yaskawa 1000 Series Drive Option - Open Collector Type PG User Manual

Page 34

Advertising
background image

34

YASKAWA ELECTRIC TOBP C730600 36C 1000-Series Option PG-B3 Installation Manual

8 Specifications

8

Specifications

Table 10 Option Specifications

Items

Description

Model

PG-B3

Compatible

Pulse Generators

Complementary, Open-collector
Single-pulse (A pulse), two-pulse (A, B pulse) or three-pulse (A, B, Z pulse)
H level: 8 to 12 V
L level: 2.0 V max.

PG Encoder Wiring

Length

Complementary: 100 m (328 ft.) maximum
Open-collector: 50 m (164 ft.) maximum

PG Encoder Power

Supply

Output voltage: 12 V

± 5%

Max. Output Current: 200 mA

Compatible Control

Modes

V/f with PG, Closed Loop Vector, Closed Loop Vector for PM motors

Maximum Input

Frequency

50 kHz

Pulse Monitor

Output

Monitor for A, B, and Z pulse output: 24 V max, 30 mA
Open-collector output

PG Encoder

Disconnect

Detection

Software detection

Ambient

Temperature

–10

°C to 50°C (14 °F to 122 °F)

Humidity

95% RH or lower with no condensation

Storage

Temperature

–20

°C to 60°C (–4 °F to 140 °F) allowed for short-term transport of the product

Area of Use

Indoor (free of corrosive gas, airborne particles, etc.)

Altitude

1000 m (3280 ft.) or lower

Advertising