3 installing the servopack, Installing the servopack, Jinstallation direction – Yaskawa Σ-mini Series User Manual

Page 13: Jinstallation sites

Advertising
background image

4.3 Installing the SERVOPACK

E - 9

Installing the SERVOPACK

J

Installation direction

D

Mount the unit vertically on wall using the mounting holes on the baseplate, with main ter-
minals at the bottom.

D

Since SERVOPACK is a self-cooling unit, supply enough space for cooling.

D

If SERVOPACKS are mounted side by side, temperature may rise because of the uneven
temperature inside the panel. Therefore, provide a fan/fans above the SERVOPACK blow-
ing down on the units.

Fan

50 mm or more

30 mm

or more

10 mm

or more

Fan

50 mm or more

J

Installation sites:

Situation

Notes on Installation

When installed in a control panel

Design the control panel size, unit layout, and cooling method so
that the temperature around the periphery of the SERVOPACK
does not exceed 50°C.

When installed near a heating unit

Suppress radiation heat from the heating unit and a temperature
rise caused by convection so that the temperature around the pe-
riphery of the SERVOPACK does not exceed 50°C.

When installed near a source of vibra-
tion

Install a vibration isolator underneath the SERVOPACK to pre-
vent it from receiving vibration.

Wheninstalledinaplacereceivingcor-
rosive gases

Corrosive gases do not immediately affect the SERVOPACK but
will eventually cause contactor-related devices to malfunction.
Take appropriate action to prevent corrosive gases.

Others

Avoidinstallationinahotandhumidplaceorwhereexcessivedust
or iron powder is present in the air.

40°C or below is preferable to maintain the reliability over a long period.

4.3

Advertising
This manual is related to the following products: