Yaskawa MP940-MW+ User Manual

Page 17

Advertising
background image

TECHNICAL NOTE

MOTION PRODUCT AND ENGINEERING GROUP

Yaskawa Electric America - 2121 Norman Drive South – Waukegan IL 60085

(800) YASKAWA - Fax (847) 887-7280

5/22/2003

17 of 34

eng/PubNumber/MCD

Running

The rest of the blocks are executed while the system is

engaged in camming (or running). The user is able to scale the cam by
modifying the variable (user variable [CamScale]) in the Cam Scale
block (14). The scale factor is a percentage of the original cam, where
100.00% represents the original cam size. A value larger than 100%
equates to an expanded cam, less equals a contract cam.


08 Torque

The torque subroutine is quite simple. Once entered from the calling program the motor

applies a variable amount of torque (based on a user variable [TorqueToApply]) and activates
output 8. It also limits the velocity of the motor (based on a user variable [Vel]). As long as input
8 is activated this is continued. Once input 8 is deactivated the servo is decelerated to stop,
output 8 is deactivated and the subroutine is exited.

09 Latch

The latch subroutine works very similarly to the move subroutine. The main difference is

the move block has been replaced with a Latch Target block (4). Additionally, the values in PLS

Advertising