Local Output functionality

Output Functionality

Description

MW+ Name

All Modes

All Modes

Local_Output1

Servo Enabled On when Servo Enabled

Local_Output2

Manual Mode On when in Manual Mode

Local_Output3 Automatic Mode On when in Automatic Mode

Local_Output4

Homed

On when system has been homed

Manual Mode

Local_Output5

Jogging Fwd On when jogging forward

Local_Output6

Jogging Rev On when jogging reverse

Local_Output7

Homing

On while homing

Local_Output8 Applying Torque On while applying torque

Automatic

Mode

Local_Output5

Index

On while indexing

Local_Output6

Gear

On while Gearing

Local_Output7

Cam

On while Camming

Local_Output8

Latch

On during latch routine

While Indexing

Local_Output6

PLS

On first third of move

Local_Output7

PLS

On second third of move

Local_Output8

PLS

On last third of move

While Latching

Local_Output5

PLS

On when Latch Window Starts

Local_Output6

PLS

On during Latch Window

Local_Output7

Latch

On if Latch Signal detected (between start & end of window)