Yaskawa MP940-MW+ User Manual
Page 32

TECHNICAL NOTE
MOTION PRODUCT AND ENGINEERING GROUP
Yaskawa Electric America - 2121 Norman Drive South – Waukegan IL 60085
(800) YASKAWA - Fax (847) 887-7280
5/22/2003
32 of 34
eng/PubNumber/MCD
Local Input functionality
Input Functionality
Description
MW+ Name (SGDH Ref)
Manual
Automatic
Local_Input1
Servo Enable
Enables Servo and Starts manual/auto programs
Local_Input2
Off*
On*
*Off Selects Manual, On Selects Automatic
Local_Input3
-
-
Not Used
Local_Input4
-
-
Not Used
Local_Input5
Jog Forward
Index
Mode Dependent
Local_Input6
Jog Reverse
Gear
Mode Dependent
Local_Input7 Home
Cam
Mode
Dependent
Local_Input8 Torque
Latch
Mode
Dependent
Sigma_ServoOn (SI-0)
-
-
Not Used
Sigma_HomeInput (SI-1)
Home SW
-
Home Switch Input
Sigma_POT (SI-2)
P-OT
Positive Over Travel
Sigma_NOT (SI-3)
N-OT
Negative Over Travel
Sigma_EXT1 (SI-4)
Alarm Reset*
*Only applicable after alarm has occurred
Sigma_EXT2 (SI-5)
-
-
Not Used
Sigma_Latch_Input (SI-6)
-
Latch Input* *Only applicable while in Latch routine