2.0 I/O Definitions


2.1 New Multi-Function Digital Input Settings


For constants H1-01 through H1-06.

Setting Display

Description

80

Disable LineShft

Closed: Line Shaft Mode is disabled

83

Advance Slave

Closed: Slave drive will increase speed without accumulating error

84

Retard Slave

Closed: Slave drive will decrease speed without accumulating error

85

Slave Trigger

Closed: The slave encoder has achieved the alignment position

86

Master Trigger

Closed: The master encoder has achieved the alignment position

87

Align Slave

Closed: The error count between the triggers will be corrected


2.2 New Multi-Function Digital Output Settings


For constants H2-01 through H2-03.

Setting Display

Description

40

Alignment Check

On = The alignment has check was within the set range

42

Aligned

On = The alignment function was performed successfully


3.0 Configuration Notes


This software document is only a supplement to the GPD515/G5 Series instruction manual. All parameters and
features not mentioned in this document have not changed.

3.1 Changed Factory Defaults of Standard Parameters


None

3.2 Minimum Programming Requirements for “Line Shaft” Operation


1. The follower VFD must be programmed for the Flux Vector control method, A1-02 = 3.
2. The follower’s run and reference sources, B1-01 and B1-02, must be set to 5:Line Shaft.