Yaskawa J7 to J1000 User Manual

Page 18

Advertising
background image

(Header Title) Application Note


Doc#: PL.J1000.01 Copyright Yaskawa Electric America, Inc.©2008 www.yaskawa.com August 1, 2008 18 of 19

Subject: Transition Guide

Product: J1000

Document: PL.J1000.01

Title: Product Transition Guide – J7 to J1000

Product Transition Guide – J7 to J1000

J7

J1000

Drive

Function
/ Parameter

Parameter

No.

Initial

Value

Parameter

No.

Initial

Value

Comments

RTS Flow Control
On / Off

n74 0

H5-07 1

J7 J1000

n74 Æ 0

H5-07 Æ 1

n74 Æ 1

H5-07 Æ 0

Low Speed Carrier
Frequency Reduction

n75 0

L8-38

Depends

on drive

capacity

J7 J1000

n75 Æ 0

L8-38 Æ 0

n75 Æ 1

L8-38 Æ 1

COPY Function
Selection

n76 Ready

o3-01 0

READ Prohibit
Selection

n77 0

o3-02 0

Possible with copy unit or remote operator.

Fault History

n78

U2-01 / 02

In the J1000, the last current fault and the last

fault can be seen in parameter U2-01 and

U2-02.

Software Version

n79

U1-25 / 26

„

7.2 Parameter Differences

Maximum Carrier Frequency -
— J7:

n46, maximum 10 kHz.

— J1000:

C6-02, maximum 15 kHz.

S-Curve Setting -
— J7:

Fixed settings.

— J1000:

Set in seconds.

Stall Prevention Level -
The stall prevention level during acceleration and constant speed run depends on the duty mode setting.
— J7:

The maximum setting of n56 / 57 is 200%.

— J1000:

Heavy Duty, The maximum setting of L3-02 and L3-06 is 150%.

Normal Duty, The maximum setting of L3-02 and L3-06 is 120%.

„

7.3 Special Software Replacement

The table below indicates replacement information for J7 drives with standard or special software.
Note:

Software ID numbers are printed on the nameplate.

J7

Software Number

Description

J1000

001x, 002x

J7 Standard Drive Software

Covered by standard software functionality.

Others

Contact your Yaskawa sales representative.


Advertising