Yaskawa Modicon 800 Series Remote I/O Network for use on Microtrac LAN User Manual

Page 12

Advertising
background image

3

SOFTWARE

11

Programming the PLC Blocks

5/24/96

• When using a Modicon PLC with 32 available drops, Modicon allows

32 input words and 32 output words per drop. One word is equivalent to
one 16 bit logic module or one channel on an 8 channel register module.
Therefore, the maximum number of logic inputs or outputs per drop is
144 (nine 16 bit modules), which assumes the use of no numerics. The
maximum number of numeric outputs per drop is 32 (four 8 channel
register output modules), which assumes the use of no logics .

• When using a Modicon PLC with 6 available drops, Modicon allows

64 input words and 64 output words per drop. One word is equivalent to
one 16 bit logic module or one channel on an 8 channel register module.
Therefore, the maximum number of logic inputs or outputs per drop is
144 (nine 16 bit modules), which assumes the use of no numerics. The
maximum number of numeric inputs or outputs per drop is 64 (eight 8
channel register input/output modules), which assumes the use of no logics.

L i m i t a t i o n s

N u m b e r

Maximum number of

Maximum number of

o f

discretes per drop

registers per drop

available

(assuming no

(assuming no

d r o p s

register modules)

discrete modules)

6

9 (16 bit modules)

8 (8 channel register

m o d u l e s )

3 2

9 (16 bit modules)

4 (8 channel register

m o d u l e s )

RD 3004-20

Advertising