Modbus response message structure – Yaskawa VS-616G5 Profibus-DP Control Card SI-P User Manual

Page 14

Advertising
background image

Page 14

VS-616G5 Option Instruction Manual: Profibus-DP Control Card SI-P

MODBUS response message structure

The MODBUS response message is built up in the following way:

If a fault occurs, the option card responds with an ERROR by setting the MSB bit
in the MODBUS Response code to one (1). When this occurs, the MODBUS data
length is set to 02H and the LOW byte for Data word 1 contains the ERROR code.

Table 11: MODBUS Response Message Structure (G5 SI-P

PDP Master)

Byte

Name

Function

16

MODBUS Function Code

MODBUS Response code.
00H:

Waiting for response from inverter.

03H:

Response for read operation.

10H:

Response for write operation.

83H:

Read command error.

90H: Write

command

error.

Other: Not supported

17

MODBUS Starting address HI

Inverter start address reference, HI byte

18

MODBUS Starting address LOW

Inverter start address reference, LOW byte

19

MODBUS Data Length

Write: No of bytes written to inverter.
Read: No. of valid bytes in the data area

20

MODBUS Data 1

HI byte for Data word 1. Read operation

21

MODBUS Data 1

LOW byte for Data word 1. Read operation

22

MODBUS Data 2

HI byte for Data word 2. Read operation

23

MODBUS Data 2

LOW byte for Data word 2. Read operation

24

MODBUS Data 3

HI byte for Data word 3. Read operation

25

MODBUS Data 3

LOW byte for Data word 3. Read operation

26

MODBUS Data 4

HI byte for Data word 4. Read operation

27

MODBUS Data 4

LOW byte for Data word 4. Read operation

28

Not used

Reserved for future use

29

Not used

Reserved for future use

30

Not used

Reserved for future use

31

Handshake register

See Handshaking Register section

Table 12: Error Code Descriptions

Error

Error Code

Description

Function error

01H

Unregistered MODBUS function code.

Address fault

02H

Parameter address (Starting address) is greater than 600H

Designate unused parameter address.

No. of Data Faults

03H

Read more than 4 words

Write more than 4 words

Data content Fault

21H

Parameter contents exceed the upper or lower limit.

22H

Parameters are changed during running or undervoltage condition.

Write Fault

23H

Write parameter during undervoltage

24H

Write parameter during calculating parameter.