6 related parameters, Arameters in, Table 4 – Yaskawa SI-W3 User Manual

Page 24: 6related parameters

Advertising
background image

24

YASKAWA ELECTRIC TOBP C730600 56A 1000-Series Option SI-W3 Installation Guide

6 Related Parameters

6

Related Parameters

The following parameters are used to set up the drive for operation with the option.

Confirm proper setting of the parameters in

Table 4

before starting network

communications.

Table 4 Related Parameters

No.

(Addr.

Hex)

Name

Description

Values

b1-01

(180)

Frequency Reference
Selection 1

Selects the frequency reference input source
0: Digital Operator - Digital preset speed d1-01 to d1-17
1: Terminals - Analog input terminal A1 or A2
2: MEMOBUS/Modbus communications
3: Option
4: Pulse Input (Terminal RP)

Default: 1
Range: 0 to 4
(Set to 3 for
LONWORKS
only)

b1-02

(181)

Run Command
Selection 1

Selects the run command input source
0: Digital Operator - RUN and STOP keys
1: Digital input terminals S†
2: MEMOBUS/Modbus communications
3: Option

Default: 1
Range: 0 to 3
(Set to 3 for
LONWORKS
only)

F6-01
(3A2)

Communications Error
Operation Selection

Determines drive response after a bUS error during
communications with the option
0: Ramp to Stop
1: Coast to Stop
2: Fast-Stop
3: Alarm Only

<1>

Default: 1
Range: 0 to 3

F6-02
(3A3)

External Fault from
Comm. Option
Detection Selection

Sets the condition for external fault detection (EF0)
0: Always detected
1: Detected only during operation

Default: 0
Range: 0, 1

F6-03
(3A4)

External Fault from
Comm. Option
Operation Selection

Determines drive response for external fault input (EF0)
detection during LONWORKS communication
0: Ramp to Stop
1: Coast to Stop
2: Fast-Stop
3: Alarm Only

<1>

Default: 1
Range: 0 to 3

F6-06
(3A7)

<2>

Torque Reference/
Torque Limit Selection
from Comm. Option

0: Torque reference / torque limit via network
communications are disabled.
1: Torque reference / torque limit via network
communications are enabled.

<3>

Default: 0
Range: 0, 1

F6-07
(3A8)

Multi-Step Speed
Enable/Disable
Selection when
NefRef/ComRef is
Selected

0: Multi-step speed reference disabled (F7 functionality)
1: Multi-step speed reference allowed (V7 functionality)

Default: 0
Range: 0, 1

TOBP_C730600_56A_0_0_E.fm 24 ページ 2011年11月2日 水曜日 午後6時10分