5 Installation Procedure

28

YASKAWA ELECTRIC TOBP C730600 27B V1000 Option PS-V10 Installation Manual

Wire Gauges and Tightening Torque

Table 6 Wire Gauges and Tightening Torque

Wire Gauges for Connecting Multiple Drives

The 24 V Power Supply Option can be wired to 10 drives in parallel.

Table 7

indicates the

proper wire gauges for connecting multiple drives.

Table 7 Wire Gauges for Multiple Drives

Disconnecting the 24 V Power Supply Option (PS-V10S / PS-V10M)

Use this procedure should it become necessary to remove the 24 V Power Supply Option

from the drive.

1. Insert a flat-blade screwdriver into the tabs on the option cover and free the option cover.

Refer to Separate the 24 V Power Supply Option Cover and Mounting Attachment on

page 17

.

2. Remove connection cables by pressing on the connector release tabs at the end of each

cable to unplug the cables.

3. Remove the mounting attachment by pressing two tabs in the direction of arrows as shown

in

Figure 23

.

Figure 23

Figure 23 Removing the Mounting Attachment

Terminal

Number

Screw

Size

Tightening

Torque

(Nxm)

Bare Wire

Pluggable Terminals

Wire

Type

Allowable

Gauges mm

2

(AWG)

Recommended

Gauges mm

2

(AWG)

Allowable

Gauges

mm

2

(AWG)

Recommended

Gauges mm

2

(AWG)

24, 0, FE M2

0.22 to

0.25

Stranded wire,
0.25 to 1.0
(24 to 17)
Single wire, 0.25
to 1.5 (24 to 16)

0.75 (18)

0.25 to 0.5

(24 to 20)

0.5 (20)

Shielded
line, etc.

Connection

Recommended Gauges mm

2

(AWG)

2 to 5 drives wired in parallel

0.25 to 0.5 (24 to 20)

6 to 10 drives wired in parallel

0.5 (20)

Advertising