5 Installation Procedure

YASKAWA ELECTRIC TOBP C730600 49A V1000 Option MECHATROLINK-II Installation Manual

17

Wiring Diagram

Figure 4

Figure 4 Wiring Diagram

<1> The FE terminal on the MECHATROLINK-II Option is supplied with a ground cable that should be connected to

the ground terminal on the drive.

If there are noise influences on communication, remove the grounding cable.

SI-T3/V

CN3

FE

<1>

NC

SRD−

SRD+

NC

NC

SRD−

SRD+

NC

NC

SRD−

SRD+

NC

MECHATROLINK
Master

Drive

Terminater

MECHATROLINK-II

Communication

Cable

shielded line