Base i/o address – Yaskawa SmartTrac DeviceNet Card User Manual
Page 22

SMART TRAC DeviceNet Card
18
••
Configuring the Smart Trac DeviceNet Card Technical Manual 3554-0070
In unusual situations, you may use several other Base I/O Addresses. If an
option must be considered, record the settings of all other cards to be placed in
the Smart Trac card stack. You must maintain unique addresses and interrupts
for all cards in the stack. The recommended optional addresses and
corresponding switch setting (SW1) are listed below:
I/O
Address
SW1 Setting
Comment
1
2
3
4
5
6
0x250
0
1
0
1
0
0
Default
0x258
1
1
0
1
0
0
Recommended as option
0x260
0
0
1
1
0
0
Recommended as option
0x268
1
0
1
1
0
0
Recommended as option
0x650
0
0
1
1
0
1
Recommended as option
0x658
1
0
1
1
0
1
Recommended as option
0x660
0
0
1
1
0
1
Recommended as option
0x668
1
0
1
1
0
1
Recommended as option
Base I/O Address