Object

ID

Object Name

GPD505

Parameter

GPD506

Parameter

Units Default

Min

Max

AO12

Motor Rated Current

n032

n033

A

Note 1

Note 2

Note 2


Notes

1. Value dependent on drive capacity. Refer to appropriate Technical Manual.
2. Proper setting is between 10% and 120% of drive’s output current rating (AI14).

4.1.7 Prohibit Frequencies – AO13, AO14, A015

These analog outputs define bands of prohibited frequencies, selected to avoid certain areas of resonant
motor vibration. Two separate bands can be defined, with a common bandwidth. When this feature is
selected, the motor is accelerated and decelerated through the prohibited areas. These objects configure
the drive as described below:

Object

ID

Object Name

GPD505

Parameter

GPD506

Parameter

Units Default

Min

Max

AO13

First Prohibit Frequency

n058

n062

Hz

0.0

0.0

400.0

AO14

Second Prohibit Frequency

n059

n063

Hz

0.0

0.0

400.0

AO15

Prohibit Frequency BW

n060

n064

Hz

1.0

0.0

25.5

4.1.8 Automatic Restarts – AO16

This analog output defines the number of automatic restarts that will be attempted under certain fault
conditions, as described below:


Restartable Faults

• Overcurrent (oC), Overvoltage (ou), Undervoltage (Uu1), Ground Fault (GF)

Non-Restartable Faults

• Overload (oL_), External (EF_), Hardware (CPF_), Fuse Blown (PUF)
• Overcurrent (oC) or Overvoltage (ou) during deceleration
• When Power Loss Ride-Through is disabled (AO18 = 0)


This object configures the drive as described below:

Object

ID

Object Name

GPD505

Parameter

GPD506

Parameter

Units Default

Min

Max

AO16

Number of Auto Restarts

n056

n060

-

0

0

10

4.1.9 Display Units – AO17

This analog output defines the display units for speed data (AO1, AO20, AI1, AI2, AI7), as described
below:

AO17 Display

Units

Description

0

Hz

Speed in Hertz (default)

1 %

% of maximum drive frequency, specified by GPD505

Advertising
This manual is related to the following products: