7. Diagnostic LEDs

7.1 RXD

This LED is lit under the following conditions:

• While the drive is attempting to establish communication with the option card, the RXD, TXD, and

FAULT LEDs blink in unison and “CALL” blinks on the digital operator. If this condition occurs, repeat
the steps outlined in Section 2.2, Drive Set-up.


• During normal operation with the drive attached and configured on the network, this LED blinks anytime

the drive receives a message addressed to it. Its blinking under these conditions indicates a “healthy”
link between the drive and the network.


• During normal operation with the drive either unattached or unconfigured on the network, this LED

blinks while the option card is communication with the drive. Its blinking under these conditions
indicates a “healthy” link between the drive and the option card.


• During use of the parameter management functions, this LED blinks during the first phase of each

function and is off upon completion (See Section 6, Parameter Management Functions).

7.2 TXD

This LED is lit under the following conditions:

• While the drive is attempting to establish communication with the option card, the RXD, TXD, and

FAULT LEDs blink in unison and “CALL” blinks on the digital operator. If this condition occurs, repeat
the steps outlined in Section 2.2, Drive Set-up.


• During normal operation, this LED blinks anytime the drive is responding to a message from the

network. Its blinking indicates a “healthy” link between the drive and the network.


• During use of the parameter management functions, this LED blinks during the second phase of each

function and remains lit upon completion (See Section 6, Parameter Management Functions).

7.3 FAULT

This LED is lit under the following conditions:

• While the drive is attempting to establish communication with the option card, the RXD, TXD, and

FAULT LEDs blink in unison and “CALL” blinks on the digital operator. If this condition occurs, repeat
the steps outlined in Section 2.2, Drive Set-up.


• During normal operation, this LED is lit if a cable loss is detected (See Section 4.4,