2 drive set-up, Rive, 2cn standoffs – Yaskawa GPD505 User Manual

Page 6: Mounting holes

Advertising
background image


Step 5.

Route the green pigtail lead from the option board to the lower left corner of the control board
and connect it to screw terminal E(G).


2CN

Standoffs

GND

Mounting Holes

Cable
connector

E(G)

Locking Tab

Locking Tab


Figure 4. Option Card Positioning

2.2 Drive Set-up

The drive must be properly configured to communicate with the option card, as described below:

GPD505

Parameter

GPD506

Parameter

Setting Description

n106 n104

1

Address

(01)

n107

n105

2

Baud Rate (9600)

n108 n106

0

Parity

(None)



NOTE: Parameter n001 must be set to 3 to change these parameters. New settings will not take

affect until drive power is cycled.


If any of these settings are incorrect, “CALL” will blink on the digital operator, as will the RXD, TXD and
FAULT LEDs. This is an indication that the drive has not yet established communication with the option
card. Once the drive has properly exchanged messages with the option card, all blinking should stop.

TM4028

7/12/2001

6

Advertising
This manual is related to the following products: