Yaskawa SmartTrac PG Card User Manual

Page 10

Advertising
background image



SMART TRAC PG Card

6

••

Installing the Smart Trac PG Card Technical Manual TM 3554-0020

2CN

Connector

4CN

Connector

CPU Card

PG Card

PS Card

Ethernet
Card

Adapter
Ring

Card

Genius PCIM

Smart Trac

Card

PC/104

Optional

Smart Trac

Smart Trac

Smart Trac

Smart Trac

Card

Inverter Control

Main Chassis

Standoffs (4
places on top of
each card)

Figure 1.

Smart Trac PG Card Stack Position

1. Power off the Smart Trac AC1. Disconnect it and tag it as "Out of

Service". Perform this and all other steps required to remove all cards
located in a stack position above the PG Card. See "Appendix D –
Removing the Smart Trac Card Stack"

2. To replace the PG card, orient the PG card so that the PC/104

connector and the J2 connector align with the PC/104 connector on the
Smart Trac CPU card and the 4CN connector on the Inverter Control
board. Be careful to align the PC/104 connector pins with the
receptacle on the Smart Trac CPU card so the pins don’t bend when the
card is pushed into place.

3. Gently but firmly push the Smart Trac PG card onto the Smart Trac

CPU card. Make sure connecting pins are in alignment and J2 mates
with 4CN before pushing the two boards tightly together. Secure the
card using four (4) metal standoffs and one (1) plastic standoff.

Advertising