Troubleshooting – Irritrol Total Control-R Series User Manual
Page 27
25
❖ Error
Solution
❖ All valves
1. Verify program: station time, watering start
will not
times, watering days schedule, current time,
turn on
current day, water budget and rain delay.
automatically
2. Check valve common wire for proper
connection.
3. Check for a shorted station; refer to
4. “How the electronic circuit breaker works”
on page 5.
5. Ensure rain sensor (if installed) is properly
connected and functioning properly. If rain
sensor is not installed, ensure the
SENSOR SWITCH
is in
BYPASS
position.
6. Check fuse, replace if necessary. See p. 27.
❖ Cannot
1. Disconnect power to controller for
program
1 minute. Reconnect power and reprogram.
2. Install fresh 9-volt alkaline battery.
3. Verify that all 16 start times are not in
use by other programs.
❖ Controller
1. Verify watering start times, current time
skips a cycle
and watering days schedule.
❖ No display
1. Check power source for tripped circuit
breaker.
2. If program module has been removed, this
is a normal battery-saving feature. Turn dial
to any position to reactivate display.
3. Disconnect power to controller for 1 min.
Reconnect power and reprogram.
4. Replace battery
5. Check fuse, replace if necessary. See p. 27.
Troubleshooting
TROUBLESHOOTING