26

Error

Solution

Valve

1. Check station times and water budget.

stays on

2. Check for Manual mode; place dial in

Run

position

.

3. Disconnect valve wire. If still on, valve

malfunction is indicated.

4. Check for manual bleed closure at valve.

Valve will

1 . Ensure dial is not in Rain/Off

not turn on

position or Rain Delay mode active.

2. Verify program: station time, watering start

times, watering days schedule, current time,
current day and water budget.

3. Make sure common wire and valve wire are

correctly connected.

4. Check for a shorted station, refer to page 5.
5. If using sensor, check sensor.
6. Check for blown fuse. Replace if necessary.

See page 27 for fuse replacement information.

“Short” or

1. See “How the Electronic Circuit Breaker

“Master Valve”

Works” on page 5 for troubleshooting

is displayed

information.

Waters too

1. Too many program start times set. Check

often

each program to determine the number of
start times assigned and remove as necessary.