KACO Powador-proLOG User Manual
Page 43
 
Page 44
Operating Instructions Powador-proLOG_EN
S e c t i o n 9 ·
C o n f i g u r a t i o n E x a m p l e
9.4 Programming criteria using the 
 
example of an inverter comparison
In this comparison, the daily energy of inverter 4 is compared 
with that of inverter 5, and an alarm is triggered if there is an 
energy yield deviation. Different inverter types can be com-
pared with one another. Enter a name for the criterion and 
activate it in the settings. You can then choose whether the 
criterion is calculated with each recording interval, or once a 
day. 
The code for the daily energy of the respective inverter is 
entered in the x
and y fi elds in the formula settings section
(here: EWR_3, EWR_4). The reason the addresses are shifted 
is because the addresses in the proLOG start with “0” (daily 
energy from inverter 5 → EWR_4). This value is then divided 
by the respective installed generator power. This means that 
values from different inverters can also be compared with one 
another (here: EWR_3 has 5.6 kW and EWR_4 has 4.8 kW of 
module power installed). The upper and lower limits are set in 
the c fi elds. Set the slope for the valid range in the m fi elds. 
You can usually leave the slope as is.