This menu shows the hardware monitor configuration

settings. Select an item then press <Enter> to display the

configuration options.

CPU0/CPU1/System Temp1/System Temp2

Temperature

The onboard hardware monitor automatically detects and

displays the CPU and motherboard temperatures.

FAN1B/FAN2B/FAN3B/FAN4B Speed

The onboard hardware monitor automatically detects

and displays the CPU , chassis and system fan speeds in

rotations per minute (RPM). If the fan is not connected to

the motherboard, it displays N/A.

CPU Voltage, 3V voltage, 5V voltage voltage

The onboard hardware monitor automatically detects the

voltage output through the onboard voltage regulators.

Smart Fan Mode Configuration

It allows you to configure the smart fan feature. You can

manually turn on the CPU fan or enable the smart fan

feature. And the CPU fan can be turned on automatically

and operate at a slower or faster speed according to

a preset temperature and duty cycle values. Refer to

Motherboard Layout on Chapter 3 Block Diagram for

CPU and system fan connectors. Note that all fans are

configured the same with a uniform configuration.

Item

Selection

Manual

Mode

Manually set the fan speed

Smart Fan

Mode

The preset the target CPU and system tem-

perature at which the system fan will start

running according to a preset duty cycle %.

30(

0

C)......13.7% duty cycle

50(

0

C)......49% duty cycle

60(

0

C)......60.8% duty cycle

72(

0

C)......78.4% duty cycle

80(

0

C)......100% duty cycle