Appendix c, Appendix c: programming generation 3 lan bypass, Programming lan bypass – Lanner FW-8895 User Manual

Page 40

Advertising
background image

36

Programming LAN Bypass

Appendix C

Network Application Platforms

Appendix C:

Programming Generation

3 LAN Bypass

The bypass function is used to link two independent

Ethernet ports when the system crashes or powers off.

This means if your system is equipped with a LAN Bypass

function, a condition in your system will not interrupt your

network traffic. Different from the previous two generations

(Gen1 and Gen2), the Lanner Bypass Gen 3 employs a

programming method to control the bypass function by

software. There are typically two communication status

for the bypass function, one is “Normal” and another is

“Bypass” status. Furthermore, the Lanner Bypass software

is capable to control the bypass status in the following 3

instances.
1. When the system powers off, it can be forced to enable

the LAN Bypass function .

2. When the system is in the just-on state which is a brief

moment when it powers up .

3. When the system is running
Please refer to the LAN_Bypass_Watchdog folder on the

Driver and Manual CD.
And the Lanner bypass possess the following features:
1. Communication through SMBUS (I2C)
2. Independent bypass status control for each pair up to

a total of 4 pairs

3. Lanner Bypass Modules can bypass systems Ethernet

ports on a host system during three instances: Just-on

(Just-on is the brief moment when the internal power

supply turns on and booting process starts), system

off, or upon software request (during run-time).

4. Software programmable bypass or normal mode
5. Software programmable timer interval:

- JUST-ON watchdog timer, used during JUST-ON, has

timer setting of 5~1275 seconds of timer interval.
- Run-Time watchdog timer, used during run-time, has

setting of 1~255 seconds of timer interval.

6. Multiple Watchdog Timers:

-Two for run-time: It is designed to give you a more

variety of controls of the bypass on port basis. By

using dedicated watchdogs for different pairs of

bypass, you have the flexibility to manage the bypass

status for them differently.
-One for just-on: It is designed to give you the precise

control of the bypass during this phase. You can use

this timer to delay enabling the bypass in just-on

state.

For sample LAN bypass code and the Bypass Manual, see

the LAN_Bypass folder on the Driver and Manual CD or

the Lanner Support Website at

http://www.lannerinc.com/

download-center/

. And browse the download center and

look for Lanner LAN Bypass Watchdog User Manual under

the Accessories folder.
Fro a description of the physical LAN ports equipped with

this function, refer to Front Panel Features in Chapter 1

Introduction.