Read associated module count – Linx Technologies HUM-xxx-DT User Manual

Page 27

Advertising
background image

– –

– –

48

49

Read Associated Module Count - Command Code = 3D
This command reads the total number of modules associated with the
current module.

For an ED, the only associated module is the AP, so the count will always
be 1. An AP outputs the number of EDs associated with it. The lack of
intelligence in an RE prevents it from being counted. An RE always outputs
a 0 because it lacks the intelligence to store its associated AP.

Read Associated Module Count Command and Response

Command

Start

Command

End

3C

3D

3E

Response

Start

Response

Param 1

End

3C

3D

Count

3E

Figure 51: Read Associated Module Count Command and Response

Output CW Signal Command and Response

Command

Start

Command

Param 1

Param 1

End

3C

42

Chan

TXPower

3E

Response

Start

Response

Param 1

End

3C

42

Status

3E

Figure 52: Output CW Signal Command and Response

Output CW Signal - Command Code = 42
This command instructs the module to output an unmodulated CW signal.
This can be useful during testing for regulatory compliance.

The module should be configured as an End Device before issuing this
command.

Chan is the channel number to be used. It ranges from 0 to 3. Figure 16
shows the channel numbers and frequencies.

TXPower is the power level of the signal. The power codes are shown in
Figure 26.

The response parameter indicates if the command was successful (00) or if
there was an error (01).

This command takes the module out of the communication stack so a
reset is required to bring the module back to normal operation.