Typical applications, Initialization complete message, Figure 58 shows a typical cir cuit using the humdt – Linx Technologies HUM-xxx-DT User Manual

Page 29: They should be connected directly to v

Advertising
background image

– –

– –

52

53

Typical Applications

Figure 58 shows a typical circuit using the HumDT

TM

Series transceiver.

An external microcontroller provides data and configuration commands. It
also controls the POWER_DOWN line to place the module into a low power
state.

A sensor is connected to GPIO_1. This sensor outputs an analog voltage
that is proportional to the parameter being measured. GPIO_1 is set as an
analog input and the microcontroller can query the voltage state of the line.

The VCCD lines are not connected in this example. These lines are unused
inputs with 20k resistors to V

CC

. They should be connected directly to V

CC

if noise on the board or in the environment could cause voltage drops on
the lines that fall below the V

IH

specification. This is not likely to be an issue

with most battery-powered devices, but could be a problem with designs
containing switching power supplies or used near motors or other sources
of high-level EMI. This should be tested with all designs.

µ

RXD

TXD

GND

VCC

GND

GND

GND

GND

GND

GND

GND

GND

GPIO

GND

17

VCC

21

GND

18

RESET

22

LNA_EN

23

PA_EN

24

CMD_DATA_OUT

26

CMD_DATA_IN

27

CTS

28

VCCD

29

GPIO_2

2

GND

25

GPIO_1

1

MODE_IND

30

ACTIVE

31

GPIO_0

32

GPIO_3

3

GPIO_4

4

ANT

19

GND

20

GPIO_

5

5

GPIO_

6

6

GPIO_

7

7

VCCD

8

VCCD

10

VCCD

11

POWER_DOW

N

12

VCCD

13

GND

9

GND

16

GND

15

GND

14

GND

GND

GPIO

GPIO

Sensor

GND

Figure 58: HumDT

TM

Series Transceiver Basic Application Circuit

Initialization Complete Message - Response Code = 7A
Once the module has completed its power-up initialization routines and
joined the network, it outputs the message shown in Figure 56.

The DType parameter is the device type that the module has assumed
during initialization. These codes are shown in Figure 57.

The microcontroller can confirm that this is the correct device type for the
application and make changes as necessary.

Device Type Codes

Device Type

Device Type Code (hex)

Access Point (AP)

31

Range Extender (RE)

32

End Device (ED)

33

Figure 57: Baud Rate Codes

Initialization Complete Message

Start

Response

Param 1

End

3C

7A

DType

3E

Figure 56: Initialization Complete Message