Absolute maximum ratings, Transceiver timings – Linx Technologies TRM-xxx-TT User Manual

Page 5

Advertising
background image

– –

– –

4

5

TT Series Transceiver Specifications

Parameter

Symbol

Min.

Typ.

Max.

Units Notes

Input

Logic Low

V

I L

0.8

VDC

9

Logic Low

V

I L

V

CC

*0.15

VDC

10

Logic High

V

I H

2

5.5

9

Logic High

V

I H

V

CC

*0.25+0.8

4.5

VDC

10

Output

Logic Low

V

OL

0.6

VDC

11

Logic High

V

OH

V

CC

–0.7

V

CC

VDC

12

Certifications

Modular Certifications

FCC, Industry Canada

1. Measured at 3.3V V

CC

2. Measured at 25ºC
3. Guaranteed by design
4. Characterized but not tested
5. PER = 5%
6. Into a 50-ohm load
7. No RF interference
8. Response time is from end of

command to start of response

9. 4.5

≤ V

CC

≤ 5.5

10. V

CC

≤ 4.5

11. I

≤ 8mA @ V

CC

≥ 5V; I ≤ 6mA @ V

CC

3.3V; I

≤ 0.8mA @ V

CC

≥ 2.5V

12. I

≤ 3.5mA @ V

CC

≥ 5V; I ≤ 3mA @ V

CC

3.3V; I

≤ 1mA @ V

CC

≥ 2.5V

13. Maximum 80ms if V

CC

< 2.6V

Figure 3: Electrical Specifications

Absolute Maximum Ratings

Supply Voltage V

cc

−0.3

to

+5.5

VDC

Any Input or Output Pin

−0.3

to

V

CC

+ 0.3

VDC

RF Input

0

dBm

Operating Temperature

−40

to

+85

ºC

Storage Temperature

−55

to

+125

ºC

Exceeding any of the limits of this section may lead to permanent damage to the device.
Furthermore, extended operation at these maximum ratings may reduce the life of this
device.

Absolute Maximum Ratings

Figure 4: Absolute Maximum Ratings

TX Vcc

TX Sx

TX MODE_IND

RX Sx

A

B

C D E

F

G

H

RX MODE_IND

AB – TX Power up Response – <80ms

BC – RX Initial Response – 8 to 50ms with no interference

CD – Data Settle – 4 to 8us

EF – Data Update Delay During Active Session – 5 to 25ms

EG – Shutdown Duration – 25 to 342ms
GH – RX MODE_IND Drop – 6 to 8ms

V

ON

TT Series Transceiver Timings

Item

Description

Minimum

Maximum

AB

TX Response from V

CC

or POWER_DOWN

1,4

8ms

TX Response from Status line while IU in idle

2

12ms

TX Response from Status line while IU / RU idle in RX

3

1ms

BC

RX Initial Response

4ms

50ms

CD

Data Settle

4µs

8µs

EF

Data Update Delay During Active Session

5ms

25ms

EG

Shutdown Duration

25ms

342ms

GH

RX MODE_IND Drop

6ms

8ms

1. From module off to V

CC

applied

2. The module is set as an IU only and is in idle pending status line activation
3. The module is set as an IU and RU and is idling in receive mode pending status line

activation or receipt of a valid packet.

4. Maximum 80ms if V

CC

< 2.6V

Figure 5: TT Series Transceiver Timings

Transceiver Timings

Warning:

This product incorporates numerous static-sensitive

components. Always wear an ESD wrist strap and observe proper ESD
handling procedures when working with this device. Failure to observe
this precaution may result in module damage or failure.

Advertising