Empire Comfort Systems DVD36FP3 EN User Manual

Page 17

Advertising
background image

23552-1-0607

Page 17

MINIMUM HOLE LOCATION DIMENSIONS FOR THROUGH THE

WALL HORIZONTAL INSTALLATIONS WITH 90 DEGREE ELBOW

OFF TOP OF FIREPLACE

Positioning the Fireplace

Determine the exact position of the appliance so the direct vent termination

will be centered (if possible) between two (2) studs. This will avoid any

extra framing. All vent kit pipes should be assembled on the unit after the

unit is moved into the final position.
Cutting the Hole (Figures 23)

After the fireplace has been positioned in its permanent location, the hole

through the exterior wall of the house can be cut. This hole must be 10"

(254mm) high x 10" (254mm) wide with its center line determined by the

amount of vertical rise and horizontal run of the termination. (See Figure

23) When locating the hole it must be noted that the bottom of the cap

must be 12" (305mm) above the ground level, and top of the cap must

be no less than 18" (457mm) below a combustible projection, and no

closer than 9" (229mm) to any wall running parallel to vent termination.
(See Figure 24)

A

CENTER OF

ELBOW

STRAIGHT

OUT

(MINIMUM)

MAXIMUM HORIZONTAL

RUN WITH NO VERTICAL

RISE AND 90° ELBOW

MAXIMUM HORIZONTAL

RUN WITH MINIMUM

VERTICAL RISE AND

90° ELBOW

minimum

Figure 24

Figure 25

FIREPLACE

SERIES

HARD ELBOW DIMENSIONS
"A"

"B"

"C"

DVD32FP

41-1/2"

(1054mm)

4"

(102mm)

6" (152mm)

DVD36FP

41-1/2"

(1054mm)

4"

(102mm)

6"

(152mm)

DVD42FP

43-1/2"

(1105mm)

4"

(102mm)

6"

(152mm)

DVD48FP

43-1/2"

(1105mm)

4"

(102mm)

6"

(152mm)

FIREPLACE

SERIES

FLEX PIPE 90 DEGREE BEND

"A"

"B"

"C"

DVD32FP

43"

(1092mm)

4-1/2"

(114mm)

6-1/2"

(165mm)

DVD36FP

43"

(1092mm)

4-1/2"

(114mm)

6-1/2"

(165mm)

DVD42FP

45"

(1143mm)

4-1/2"

(114mm)

6-1/2"

(165mm)

DVD48FP

45"

(1143mm)

4-1/2"

(114mm)

6-1/2"

(165mm)

Figure 23