Specifications fireplace dimensions – Empire Comfort Systems DVD36FP3 EN User Manual

Page 7

Advertising
background image

23552-1-0607

Page 7

Figure 1

Dim

DVD32

DVD36

DVD42

DVD48

A

34"

864mm

37"

940 mm

43"

1092 mm

49"

1245 mm

B

31"

787 mm

34"

864 mm

40"

1016 mm

46"

1168 mm

C

23 1/16"

585 mm

23 1/16"

585 mm

25 1/16"

636 mm

25 1/16"

636 mm

D

35 5/8"

905 mm

35 5/8"

905 mm

37 5/8"

956 mm

37 5/8"

956 mm

E

32 3/4"

832 mm

32 3/4"

832mm

34 3/4"

883 mm

34 3/4"

883 mm

F

16 3/8"

416 mm

16 3/8"

416 mm

16 3/8

416 mm

16 3/8"

416 mm

G

24 1/2"

622 mm

24 1/2"

622 mm

26 1/2"

673 mm

26 1/2"

673 mm

H

7 1/8"

181 mm

7 1/8"

181 mm

7 1/8"

181 mm

7 1/8"

181 mm

I

21 1/2"

546 mm

24 1/2"

622 mm

30 1/2"

774 mm

36 1/2"

927 mm

J

10 3/4"

273 mm

12 1/4"

311 mm

15 1/4"

387 mm

18 1/4"

464 mm

K

9 1/4"

235 mm

9 1/4"

235 mm

9 1/4"

235 mm

9 1/4"

235 mm

RIGHT SIDE VIEW

J

H

K

Remote Control

Options & Accessories

Description

FRBC

Millivolt Batt. Remote ON/OFF

FRBTC

Millivolt Batt. Remote T-Stat

FREC

Direct Ignition/Millivolt 120V ON/OFF Remote

TMW

Millivolt Wireless Wall Thermostat

TRW

Millivolt Reed Switch Wall Thermostat

FWS-1

Direct Ignition/Millivolt Wall Switch

Venting Options

Description

DVVK-4TS

Top vent kit (HORZ.) - 4½" to 6" (114.3mm to 152mm) wall
thickness

DVVK-4T

Top vent kit (horz.) - 8" to 12" (203mm to 305mm) wall thickness

DVVK-4R

Rear vent kit (horz.) - 5" to 7" (127mm to 178mm) wall thickness

DVVK-4V

Vertical vent kit

DVVK-4F

Horizontal flex vent kit (4' FLEX)

DVVK-4RE

Horizontal round termination (wall thickness up to 11 7/16")

DV822

Vinyl siding kit for DVVK-4RE

DVD32

DVD36

DVD42

DVD48

Input BTU/Hr Maximum

18,000

20,000

25,000

28,000

BTU/Hr Minimum (millivolt only)

14,000

14,000

18,000

20,000

KWH (Maximum)

5.3

5.9

7.3

8.2

(Minimum)

4.1

4.1

5.3

5.9

NAT.

Orifice

#46 (.081")

P-254

2.10 mm

P-288

#42 (.0935")

P-286

#39 (.0995")

P-285

Air Shutter Opening

1/16" (1.6mm)

1/16" (1.6mm)

3/16"(4.8mm)

1/8" (3.2mm)

LP

Orifice

#56 (.0465")

P-287

#55 (.052")

P-182

1.45 mm

P-208

#52 (.0635")

P-185

Air Shutter Opening

1/4" (6.3mm)

5/16" (7.9mm)

5/16" (7.9mm)

5/16" (7.9mm)

Height without standoff

32 3/4" (832mm)

32 3/4"(832mm)

34 3/4"(883mm)

34 3/4"(883mm)

Width

34" (864mm)

37" (940mm)

43" (1092mm)

49" (1245mm)

Depth

16 3/8" (416mm)

16 3/8" (416mm)

16 3/8" (416mm) 16 3/8" (416mm)

Gas Inlet Shutoff Valve (Pipe)

1/2 NPT

1/2 NPT

1/2 NPT

1/2NPT

NOTE: Air shutter settings

are factory minimum

settings. Some venting

configurations may

require minor air shutter

adjustments for optimum
performance

.

SPECIFICATIONS