7. Remove outside mounting plate with tube attached from wall. Mark

and cut the extra length of the 6 5/8” (168mm) diameter tube from

the opposite end. Do not crimp or enlarge tube.

8. Attach the 4” (102mm) diameter flue outlet tube onto the rigid

venting system or directly to fireplace. Ensure the 4” (102mm)

diameter flue outlet tube is placed as far as possible onto the rigid

venting system. Mark the 4” (102mm) diameter flue outlet tube

2 1/2” (64mm) beyond the vinyl siding kit or wall. See Figure

3B. Remove the 4” (102mm) diameter flue outlet tube from rigid

venting system. When installing directly to fireplace, tape gasket

needs to be used.

9. Mark or wrap tape completely around the tubes at the marked points

to help in making a true cut. Do not crimp or enlarge tubes.

10. From outside: Push the 6 5/8” (168mm) diameter inlet tube/mount-

ing plate onto end of rigid venting system to correct position. Fasten

the outside mounting plate to the vinyl siding kit or wall with (4)

10 x 1 1/2” screws. (Ensure upward slope).

11. From inside: Attach the inlet tube to the collar on the back of

the fireplace (or the rigid venting system) using (3) self tapping

screws.

12. Seal the 4” (102mm) diameter flue outlet tube. Follow instructions

and diagram (Figure 4).

13. Fasten 4” (102mm) diameter flue outlet tube in place. Do not “twist”

the flue outlet tube into the fireplace collar (or rigid venting sys-

tem). Hold the tube by the seam and push in using a perpendicular

“rocking” motion. This ensures the seam on the tube stay intact.

14. Fasten vent cap end using (3) 10 x 1/2” screws to mounting plate.

Sealing 4” (102mm) Diameter Flue Outlet Tube

OUTSIDE WALL

MEASURE

VINYL SIDING KIT DV822

OUTSIDE MOUNTING

PLATE

EXT. WALL
SURFACE OR
VINYL SIDING KIT

FLUE
PIPE

CUT

2 ½”

BEYOND EXTERNAL

WALL SURFACE OR

VINYL SIDING KIT

Figure 3A

Figure 3B

1”

VENT CAP END

APPLY SEALANT

ON THE INSIDE

DO NOT PLACE

OVERLAPPED

SECTION OVER

THE SEAM IN THE TUBE

Figure 4

Note: Tape gasket to be applied prior to installing to fireplace flue outlet tube

only. Tape gasket should not be used when mating the flue outlet tube to a rigid

venting system.

DVVK-4RE VENT KIT INSTALLATION INSTRUCTIONS (continued)