Vent system identification – Empire Comfort Systems DVD36FP3 EN User Manual

Page 23

Advertising
background image

23552-1-0607

Page 23

I

nstalling Vent Components (Figure 36)

Begin the vent system installation by installing the first Simpson

Duravent component, 90° elbow to the starting collars or straight

pipe on the top of the appliance, then the straight pipe length and

then horizontal or vertical termination kit.
NOTE: All outer connection joints must be sealed with aluminum

tape, screws or silicone sealant rated above 300°F/149°C. The

inner flue joints do not require any sealant.

Simpson Duravent vent system components lock into place by

sliding the concentric pipe section with four (4) equally spaced

interior beads onto the appliance collar or previously installed

component end with four (4) equally spaced indented sections.

When the internal beads of each starting outer pipe line up, rotate

pipe section clockwise 90° (approximately 3 inches). The vent pipe

is now locked together.
Continue adding components per the pre-planned vent system

configuration. Be certain that each succeeding vent component

is securely fitted and locked into the preceding component in the

vent system.

Figure 36

WALL THIMBLE

(MAXIMUM OF

THREE 90 ELBOWS)

(MAXIMUM OF

TWO 90 ELBOWS)

Special Venting Components (Simpson Duravent)
See Empire Comfort Systems Retail Price List for Simpson Duravent part numbers

and pricing.

Special DV Vent Kits

Available from Empire Comfort Systems, Inc. dealers.

DVVK-4FV Vertical Flex Vent Kit 4" x 7"
DVVK-4V

Direct-Vent Fireplace Vent Kit - Vertical, Includes SD-991, SD-

953, and SD-943

DVVK-4T

Direct-Vent Fireplace Vent Kit for Top Vent, Thru-the-wall, 8 to

11 inch wall thickness, Includes SD-911, SD-985, SD-990 and

SD-942

DVVK-4R

Direct-Vent Fireplace Vent Kit for Rear Vent, 5 to 7 inch wall

thickness, (standard thru-the-wall venting) Includes SD-908, SD-

985 and SD-942

DVVK-4RE Direct-Vent Fireplace Vent Kit for Rear Vent, Thru-the-wall, 5 to

13 3/4 inch wall thickness

DVVK-4TS Direct-Vent Fireplace Vent Kit for Top Vent, Thru-the-wall, 5 to

7 inch wall thickness, Includes SD-908, SD-985, SD-990 and

SD-942

VIB6A

Vertical Inlet Baffle Kit for 6 5/8" dia.

VIB7A

Vertical Inlet Baffle Kit for 7" dia.

VENT SYSTEM IDENTIFICATION

Advertising