23552-1-0607

Page 27

CAUTION: Sharp edges, use protective gloves when

installing.
Tools Needed for Installation:

Sheet metal snips

5/16” nut driver

Phillips head screwdriver - #2

High temperature sealant or furnace cement rated for continuous use

at 1,000

o

F minimum

Measuring tape

Parts Verification

See parts list on page 29 to verify components included in this vent

kit prior to installation.

NOTE: If installing onto wood, lap, or vinyl siding, the vinyl siding

kit should be used (sold separately, part number DV-822).
The vinyl siding vent kit, DV-822, is available from Empire Comfort

Systems, Inc. The depth is 3” (76mm), which enables the vent cap to

be extended away from vinyl siding or projections. The wall depth plus

the additional 3” (76mm) depth of the vinyl siding vent cap extension

should not exceed a total depth of 13 3/4” (349mm).
If wall depth exceeds 13 3/4” (349mm), extend system using

6 5/8” (168mm) x 4” (102mm) rigid venting (See Fireplace Instructions

for approved lengths) See Figure 2.

Installing Wall Thimble/Firestop Assembly

1. Fix fireplace to permanent location. If using rigid venting system,

install up to the location where it will exit the building.

2. Cut hole in wall for wall thimble/firestop assembly (Figure 1) into

your combustible wall. Note: On brick or block exterior wall a 7”

(178mm) diameter hole needs to be cut.

Measure the total wall thickness to determine whether or not the

extension thimble is to be used. If the combustible wall depth is

over 5 3/8” (137mm), then the extension thimble should be used

(Figure 1).

3. Install the wall thimble assembly through the framed opening so the

firestop plate is on the interior wall (Figure 1). Telescope section

should extend all the way through the exterior wall. Attach with

(4) 10 x 1” screws.

4. When placing the vent cap on an exterior wall covered with com-

bustibles such as wood, lap, or vinyl siding, install the vinyl siding

kit to the exterior wall sheathing.

Figure 1

Figure 2

Cutting Vent Tubes

This is the most important part of the installation. With the

fireplace (and the rigid venting system if used) fixed to its perma-

nent location, the 6 5/8” (168mm) diameter air inlet tube and the

4” (102mm) diameter flue outlet tube are to be marked and cut

using the following procedure.

5. Attach the inlet tube to the outside mounting plate. Align

tinnerman clips on the tabs of the air inlet tube to the holes on

outside mounting plate, and fix with (2) #10 x 1/2” screws.

6. With the vinyl siding kit installed to wall (if necessary), insert the 6

5/8” (168mm) diameter tube with outside mounting plate attached

through hole in wall. Connect to collar on fireplace or rigid vent

system. Measure between wall or vent cap extension and outside

mounting plate (Figures 3A and 3B).

X

X = 13/3/4” MAX

TOTAL WALL THICKNESS

(SUBTRACT 3” IF USING THE

DV822 VINYL SIDING KIT)

½” AIR
SPACE
CLEARANCE

11”

9”

NOTE: SPACING FLANGE

INSTALLED TO TOPSIDE

INTERIOR WALL

EXTENSION

THIMBLE

DVVK-4RE VENT KIT INSTALLATION INSTRUCTIONS