PD6830 Pulse Input Rate/Totalizer Instruction

Manual

14

Connections (continued)

ISO+

Isolated signal input positive terminal connection.

ISO-

Isolated signal return/negative terminal connection.

S+

Signal input positive terminal connection.

S-

Magnetic pickup (coil) signal return/negative terminal connection.

COM

Signal return/negative, DC power return/negative, Contact closure reset
return/negative terminal connection.

RST+

Contact closure reset pull-up to 3 VDC.

P+

DC Power positive terminal connection.

LP+

4-20 mA transmitter DC power positive terminal connection.

LP-

4-20 mA transmitter regulated current output terminal connection.

Refer to Figure 1 for terminal positions.

WARNING

Observe all safety regulations. Electrical wiring should be
performed in accordance with all agency requirements and
applicable national, state, and local codes to prevent damage to
the meter and ensure personnel safety.

ISO+

ISO-

S+

S-

COM

RST+

P+

LP+

LP-

Figure 1. PD6830 Connector Board