PD6830 Pulse Input Rate/Totalizer Instruction

Manual

35

Manual or Automatic Total Reset Function (t rST)

For manual reset, select PROGRAM

 t rst  man and then next select whether

manual reset will be enabled (Enabl) or disabled (dsabl) using the up arrow key and
by then pressing the Enter/Ack button to accept. Disabling reset will avoid
inadvertent resets of the total via the front reset button or external reset contact.

For automatic reset, select PROGRAM

 t rst  Auto T DELAY and enter reset

delay time in seconds. Once the set point is reached, the meter waits for a
programmed amount of time (T DELAY) and then resets the total to zero.

The meter may be automatically reset based on the value programmed in the
Advanced menu: INDICAT

 alrm  total  SEt.

Press the Enter/Ack button, at any time, to accept a setting; otherwise press the
Menu button to exit without saving changes.

t rst

SeTUP

nman

T RESET

Auto

T RESET

Enter Reset Delay

(seconds)

0

0010

T DELAY

enabl

MAN RST

DSABL

MAN RST